9.6.5 SFC program parameter setting and batch conversion
Set the parameters and convert them for the created SFC program.
1) Click on [Option], [SFC parameter setting] and then
the [Program parameter] menu on the PROGRAM
EDIT screen.
2) The PROGRAM PARAMETER screen will open.
The created SFC program will be listed, so double-
click on "Initial setting".
3) The PROGRAM PARAMETER SETTING dialog box
will open.
Set "Start setting" to ‘Automatic start'.
After setting, click on the OK
button.
(Continued on next page)
Task (execution timing) setting
1. Normal task
Execute at motion cycle (dead time)
2. Event task
• Execute at constant cycle (0.8ms, 1.7ms,
3.5ms, 7.1ms, 14.2ms)
• Execute upon input of external interrupt QI60
I0 to I15
• Execute upon interrupt from PLC (I0 to I15)
(GINT command)
3. NMI task (Non-Maskable Interrupt)
Execute upon input of external interrupt QI60 I0
to I15
Since it has higher priority than external input of
event task, it is executed preferentially even if
the interrupt inhibit (DI) occurs.