PC Status: display whether connect to PC
software
2.1.5.4.2 Volume Settings
Line in: Adjust the input volume of line In.
Treble: Adjust the conference unit fidelity
audio treble and line output treble.
Bass: Adjust the conference unit fidelity audio
bass and the bass of line output.
Line out: adjust the volume of conference unit
fidelity audio and line output
Infrared: adjust the volume of interpreters
output channel (corresponding to the CR-
DIG5201 rear panel CH0 ~ CH15
microphone, separate output). Note that CH0 is
original sound, only be adjusted by the Infrared
menu, cannot be controlled by treble, bass,
Line-out menu, and have no AGC ANC AFC
function.
2.1.5.4.3 Unit Management
1 start coding ID
the so-called conference unit ID setting, refer
to endow a unique address to every conference
unit (including the translation unit and speak unit)
for host identification.
Steps of coding ID
After connecting the conference system,
open the conference host power, select the "unit
management" and start coding ID, the display
shows as follows:
All speech units and translation units display
as follows
Speech units display
Translation units display
At this point press microphone buttons of
conference unit one by one to set ID. Conference
unit microphone button indicators blink once or
stay lit, suggesting that the current ID is unique. If
the button indicators blink several times and then
stay lit, indicating that at least there are 2
machines having the current ID. Conference unit
microphone button indicators stay lit, the setting
of ID is successful. However, if the indicator light
keeps blinking, the setting of ID is unsuccessful.
After finishing the setting, press Stop Coding
ID to exit setting. When all the indicators
extinguish, the system enters the normal state. If
the ID repeats, microphone key indicator of
repeated ID conference unit will flash, thus the
repeated ID should be reset. The host system
information menu will warn about the repeated ID
as well.
When the host is re-powered, the system will
automatically detect that whether the ID is
repeated.